The 30 Series is a wide range pressure calibrator that fits easily into a shirt pocket with 0.05% of reading accuracy.
The 30 Series is a wide range pressure calibrator that fits easily into a shirt pocket with 0.05% of reading accuracy. There are no external transducers! Everything is built in! There are two models to choose from: Model 31s have one sensor, while Model 33s have two sensors.
*ATEX version is optional
Accuracy Vacuum operation is not specified for 600 PSI (40 bar/4000 kPa models and higher. However, all models can be safely connected to vacuum. Temperature Electrical Intrinsic Safety *ATEX version is optional Other Certifications |
Connections Media Compatibility Note: Over-range occurs at 110% of full scale, causing "HP Over" or "LP Over" to be displayed. Standard factory setting is 1"H2O = 0.036126 PSI (density of water @ 4°C). Specify at time of order if you require a different density (e.g., for water @ 68°F, 1"H2O= 0.036063 PSI). Power Enclosure Sensor |
Pressure Ranges
Pressure Ranges | Pressure Units and Resolution | |||||||||||||
PSI | bar | kPa1 | Over pressure |
PSI | kg/cm2 | Inch Hg | inch H2O | mm Hg | cm H2O | mm H2O | kPa | MPa | mbar | bar |
162
|
13 & 4
|
1004
|
6.5x
|
0.001
|
0.0001
|
0.001
|
0.01
|
0.01
|
|
1
|
0.01
|
|
0.1
|
0.00014
|
362
|
23 & 4
|
2004
|
3.0x
|
0.001
|
0.0001
|
0.001
|
0.01
|
0.01
|
|
1
|
0.01
|
|
0.1
|
0.00014
|
300
|
20
|
2000
|
2.0x
|
0.01
|
0.001
|
0.01
|
0.1
|
0.1
|
1
|
|
0.1
|
|
|
0.001
|
600
|
40
|
4000
|
2.0x
|
0.01
|
0.001
|
|
|
|
|
|
0.1
|
0.0001
|
|
0.001
|
1500
|
100
|
10000
|
2.0x
|
0.1
|
0.01
|
|
|
|
|
|
1
|
0.001
|
|
0.01
|
3000
|
200
|
20000
|
1.5x
|
0.1
|
0.01
|
|
|
|
|
|
1
|
0.001
|
|
0.01
|
5000
|
300
|
30000
|
1.5x
|
0.1
|
0.01
|
|
|
|
|
|
1
|
0.001
|
|
0.01
|
1- kPa versions are restricted to kPa, MPa, bar and/or millibar, depending on pressure range.
2 - PSI versions with ranges of 36 PSI and lower include all possible scales except bar.
3 - Bar versions with ranges of 2 bar and lower include all scales except inch Hg, cm H2O and MPa.
4 - Applies to bar and kPa version only.
Second Pressure Range | ATEX ONLY | |||||||
300 PSI | 600 PSI | 1.5K PSI | 3K PSI | 5K PSI | ||||
20 bar | 40 bar | 100 bar | 200 bar | 300 bar | ||||
2K kPa | 4K kPa | 10K kPa | 20K kPA | 30K kPa | ||||
First Pressure Range | ||||||||
16 PSI | 1 bar | 100 kPa |
x
|
x
|
x
|
x
|
x
|
|
36 PSI | 2 bar | 200 kPa |
x
|
x
|
x
|
x
|
x
|
|
300 PSI | 20 bar | 2K kPa |
n/a
|
n/a
|
x
|
x
|
n/a
|
Please visit Industrial Process and Sensor for more info.