SERIES 1800 HIGH ACCURACY 4 mA to 20 mA LOOP-POWERED INDICATORS
The Model 1800 Attachable Loop-Powered Digital Indicator can be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. It is simply inserted between the transmitter body and the connector. The indicator is programmable to display a range of –1999 to 9999, and it may be tilted for better viewing. Also, there is user selectable digital filtering to improve readability in rapidly varying pressure applications. All parameters are stored in non-volatile
memory so that reprogramming is not necessary in the event of a power failure.
IPS will calibrate the indicator to your transmitter at no additional cost. Simply tell us how you want it set up.
SPECIFICATIONS
Display: 0.4 ? Liquid Crystal Display
Digits: 4, from –1999 to 9999
Accuracy: ±0.2 % Full Scale, ±1 digit
Update rate: 5 times/second
Filtering: Digital, field selectable .2, .5, 1 or 1.5 seconds, display only
Range: The 4 mA to 20 mA signal from the transmitter can be assigned any display value within the display range. Both scaling points are individually adjustable using the push buttons inside the case
Power Supply: Loop-powered - no additional power supply required. Maximum current rating is 40 mA and voltage drop of 3 Vdc, unregulated
Temperature Ranges: Ambient 32 °F to 122 °F (0 °C to 50 °C) Effect is ±0.006 % Full Scale/°F
Storage: –22 °F to 176 °F (-30 °C to 80 °C)
Electrical: Requires NOSHOK transmitter with 4 mA to 20 mA (2-wire) output and Hirschmann (DIN 43650A) connector
Environmental: IP65, NEMA 4X according to EN 60529/IEC 529 Protection
Electromagnetic rating: CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection
Case material: ABS plastic with polycarbonate window
Weight: Approximately 3 oz.