Quantcast Industrial Process and Sensor: Honeywell Two-wire transmitter Models 415 and 440
  About    Home Page    Order Info    Thermocouples    My Account    Shopping Cart    Legal/Privacy    Contact  
Honeywell Two-wire transmitter Models 415 and 440
Honeywell Two-wire transmitter Models 415 and 440 SKU: AP411, AP 412, AP415, AP416
Description and Specs

Two-wire transmitter Models 415 and 440 offer rugged, stainless steel construction suitable for even the harshest working environments. These models are available with zero and span adjustments and operate with a supply voltage from 15 to 32 VDC. Two-wire, 4-20mA output is provided. Both models set the accuracy standards for their competitive niches. The Model 415 offers an accuracy of 0.1% while the Model 440 offers an accuracy of 0.25% F.S. A wide range of electrical connectors are offered, with a DIN-type as standard on the Model 440. This connector offers many significant advantages to the user, including flexibility to use any cable size between 4.5 mm and 14 mm or utilize a 1/2” NPT conduit fitting. It has the convenience and advantage of being a solderless and water-resistant connection, as well as allowing the user to turn the vibration-proof mating connector in any direction to achieve optimum cable clearance and cable/conduit run paths. These characteristics and extremely competitive prices make the 415 and 440 units perfect for industrial transmitter applications like bulk liquid inventory control, steam management, and other power plant applications.

Specs415440
Pressure Ranges 2 to 20,000 psi 5 to 10,000 psi
Accuracy (min) +0.1% F.S. +0.25% F.S.
Combined Non-Linearity,Hysteresis,Non-Repeatability 0.10% BFSL 0.2% BFSL
Output 4-20mA 4-20mA
ResolutionInfinite Infinite
Temperature, Operating -20°F to 200°F -20°F to 185°F
Temperature, Compensated 60°F to 160°F 30°F to 130°F
Temperature Effect
-Zero (max) 0.005% F.S./°F. 0.01% F.S./°F
-Span (max)0.007% Rdg./°F 0.01% Rdg./°F
Supply (acceptable) 15 to 32VDC 9 to 32VDC
Max Load Resistance*1000 ohms 1000 ohms
Wiring Code (std) Sensotec #23 Sensotec #36
Electrical Termination (std)PTIH-10-6P or equiv. DIN 43650 (Hermatic stainless) Water Resistant
Mating Connector (not incl.)PT06A-10-6S or equiv. DIN mating connector with solderless terminal**
Zero & Span Adjustment Access through o-ring Located under. sealed screws top cover
Media Liquid, Gas Liquid, Gas
Overload-Safe50% over capacity 50% over capacity
Overload-Burst200% over capacity 200% over capacity
Pressure Port
2 to 10,000 psi 1/4-18 NPT female1/4-18 NPT female
20,000 psi 9/16-18 UNF per AE F-250-C NA
Wetted Parts MaterialStainless Steel Stainless Steel
Type Gage or Absolute Gage or Absolute
Weight13 oz. 13 oz.
Case Material Stainless Steel Stainless Steel
*Maximum load resistance is 500 ohms at 23VDC.
**Specify cable dia. can handle 4.5 mm to 14 mm or 1/2” NPT conduit fitting.

© 2003-2009 Industrial Process and Sensor. All rights reserved.

All product names throughout this website are trademarks of their respective holders.