The transmitter is best applied with clean liquid or gas media including water, oil and air.
| Range: |
-S0_1: 0 to 5 psi (0.34 bar) 0 to 11' (0 to 3.4m) wc -S2_1: 0 to 15 psi (1 bar) 0 to 34' (0 to 10.4m) wc -S4_1: 0 to 30 psi (2 bar) 0 to 69' (0 to 21.1m) wc |
| Accuracy: |
±
0.25% of full span |
Supply voltage: |
13 to 30 VDC |
| Max. loop resist.: |
1300 Ohms @ 30 VDC |
| Signal output: |
4-20 mA, two-wire |
| Calibration: |
None, fixed span |
| Process temp.: |
F: 0° to 200° C: -18° to 93° |
| Temp. comp.: |
Automatic |
| Proof pressure: |
2 x full span |
| Burst pressure: |
> 35 x full span |
| Process mount: |
1/4" NPT |
| Enclosure rating: |
NEMA 4X (IP65) |
| Probe material: |
316 SS & 316L SS |
| Termination: |
-S_01: 3' (1m) cable -S_11: Junction box with 1/2" NPT conduit connector |
| Cable material: |
Polyurethane |
| Cable type: |
2-conductor, shielded |
| Classification |
General purpose |
| CE compliance: |
CE: EN55022, EN55024, EN61000 |
Please visit Industrial Process and Sensor for more info.