The transmitter is broadly selected for atmospheric bulk storage, day tank, waste sump, process vessel, IBC tote, 55-gallon drum and waste sump applications.
Range: |
LU27: 4" to 8.2'(10cm to 2.5m) LU28: 8" to 24.6' (20cm to 7.5m) LU29: 8" to 32.8' (20cm to 10m) |
Accuracy: |
±0.2% Range |
Resolution: |
LU27: 0.019" (0.5mm) LU28/29: 0.078" (2mm) |
Beam width: |
LU27: 2" (5cm) dia. LU28/293: 3" (7.6cm) dia. |
Dead band: |
LU27: 4" (10cm) LU28/293: 8" (20cm) |
Memory: |
Non-volatile |
Supply voltage: |
24 VDC |
Consumption: |
0.5 W |
Loop resist.: |
500 Ohms @ 24 VDC |
Signal output: |
4-20 mA, two-wire |
Signal invert: |
4-20 mA or 20-4 mA |
Configuration: |
WebCal® PC Windows® USB 2.0 |
Fail-safety: |
4 mA, 20 mA, 21 mA, 22 mA or hold last |
Process temp: |
F: -4° to 140° C: -20° to 60° |
Temp. comp.: |
Automatic |
Ambient temp: |
F: -31° to 140° C: -35° to 60° |
Pressure: |
MWP = 30 psi (2 bar) |
Enclosure rating: |
NEMA 6P |
Encl. material: |
Polycarbonate |
Trans. material: |
PVDF |
Cable jacket mat.: |
Polyurethane |
Cable type: |
4-cond. shielded |
Cable length: |
10' (3m) |
Process mount: |
LU27: 1" NPT (1" G) LU28/29: 2" NPT (2" G) |
Mount gasket: |
Viton® |
Classification: |
General purpose |
Compliance: |
RoHS |
Approvals: |
CE, cFMus |
Please visit Industrial Process and Sensor for more info.