Flowline EchoSafe® Explosion Proof Two-Wire Ultrasonic Level Transmitter

Flowline EchoSafe® Explosion Proof Two-Wire Ultrasonic Level Transmitter



Please Call 1-618-465-7623 for a Quote on this product!

Description
FM approved explosion proof for use in hazardous applications, the two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' or 10 m, and is well suited for challenging corrosive, slurry or waste liquids. Push button calibrated, the transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified area. Media examples include sodium hypochlorite, diesel fuel and paint. The integral display and push button module enable fast and simple calibration.

Specifications
Range:
XP88: 8" to 24.6' (20cm to 7.5m)
XP89: 8" to 32.8' (20cm to 10m)
Accuracy:
± 0.2% of max. range
Resolution:
0.079" (2mm)
Beam width:
3" (7.6cm) dia.
Dead band:
8" (20cm)
Display type:
LCD, 6-digits
Display units:
inch, cm, percent, feet or meter
Memory:
Non-volatile
Supply voltage:
18-28 VDC (loop)
Loop resistance:
250 Ohms max @ 24 VDC
Signal output:
4-20 mA, two-wire
Signal invert:
4-20 mA or 20-4 mA
Calibration:
Push button (3-button)
Fail-safe:
4 mA, 20mA, 21 mA, 22 mA or hold last
Process temp.:
F: -4° to 140°
C: -20° to 60°
Temp. comp.:
Automatic
Electronics temp.:
F: -40° to 160°
C: -40° to 71°
Pressure:
30 psi (2 bar)
Enclosure rating:
NEMA 4X (IP65)
Enclosure mat.:
Aluminum
Window mat.:
Glass
Transducer mat.:
PVDF
Process mount:
2" NPT
Conduit entrance:
Dual, 1/2" NPT
Mount gasket:
Viton®
Compliance:
RoHS
Classification:
Explosion Proof
Approvals:
FM:Class I, Div I
Groups A, B, C, D
Class II/III, Div I,
Groups E, F, G