Fluke Model 718 Pressure Calibrator SKU: FL
RETAIL: 1,885.00 PRICE: 1,795.00
|
you Can Buy This Product Online!
|
Description
|
|
Fluke 718 Series Pressure Calibrator | :
Measurement Accuracy |
Pressure |
Fluke 718 30G |
|
|
|
Range: |
-12 to 30 PSI, -850 mbar to 2 bar (internal sensor) Over
Pressure 3xFS |
Resolution: |
0.001 psi, 0.1 mbar |
Accuracy: |
0.05% full scale |
Functions: |
Zero, Min, Max, Hold, Damp |
|
Note: for use with non-corrosive gasses |
|
|
Fluke 718 100G |
|
|
|
Range: |
-12 to 100 PSI, -850 mbar to 7 bar (internal sensor) Over
Pressure 3xFS |
Resolution: |
0.01 psi, 1 mbar |
Accuracy: |
0.05% of full scale |
Functions: |
Zero, Min, Max, Hold, Damp |
|
Note: for use with non-corrosive gasses |
|
|
Fluke 718 series |
|
|
|
|
via pressure module connector |
Range: |
29 pressure modules, 0-1 inH20 to 10,000 psi, 2.5 mbar to
700 bar |
|
Over pressure per pressure module specs |
Resolution: |
Per pressure module specs |
Accuracy: |
To 0.025% of full span, per pressure module
specs |
Functions: |
Zero, Min, Max, Hold, Damp |
|
Note: media compatibility per pressure module
specs, |
|
|
Source Pressure, built in pump |
|
Range: |
-12 PSI or -820 mbar to full scale |
|
|
|
Supported Pressure Units; psi, in. H20 (4 °C), in. H20
(20 °C), cm H20 (4 °C), |
|
cm H20 (20 °C), bar, mbar, kPa, inHg, mmHg,
kg/cm | |
Specifications |
Loop Power |
Range: |
24 V dc |
Accuracy: |
+/- 10% |
|
Note: Drive; 20 mA into 1000 Ω for battery >6.8V; 700
Ω for battery 5.8 to 6.8 V | |
Measure Accuracy: |
Range: |
0 to 24 mA |
Resolution: |
0.001 mA |
Accuracy: |
0.025% + 1 count | |
Display |
|
LCD, 5 digit pressure and current
simultaneous | |
Environmental Specifications |
Operating temperature
|
|
Storage temperature
|
|
Humidity (Without Condensation)
|
|
95% (10ºC to 30ºC) |
|
75% (30ºC to 40ºC) |
|
45% (40ºC to 50ºC) |
|
35% (50ºC to 55ºC) | |
Operating Altitude |
|
Safety Specifications |
Safety |
|
CSA C22.2 No.
1010.1:1992 | |
Maximum voltage |
|
Mechanical & General
Specifications |
Size |
|
216 mm L x 94 mm W x 67 mm (8.5 in. L X 3.72 in. W X
2.61in.) | |
Weight |
|
Warranty |
|
Shock & Vibration |
|
Random, 2G, 5-500 Hz |
|
1m drop test | |
Battery type |
|
Two 9V batteries, ANSI/NEDA 1604A or IEC 6LR61 |
|
Battery life: 4 to 20 hours, typical, depending on
functions | |
|