    Type | 
    Product 
    Description | 
    Performance 
    Features | 
    Applications | 
  
    | GG | 
    Most popular and 
    widely applied of all glass insulations. A color-coded fiberglass braid 
    saturated with a high-performance resin is used for insulation of the single 
    conductors and jacket. | 
      
      
      Designed for continuous use  to 950°F (510°C);
      
      intermittent use to 1200°F (648°C).
      
      Good moisture and chemical resistance, fair abrasion resistance |  | 
  
    | KK | 
    Very tough, 
    durable Kapton* double wrap of heat-fused polyimide tape is applied over 
    each conductor.  Each insulated single conductor is coated with an ANSI 
    color-coded polyimide varnish.  The jacket consists of a double-wrapped 
    heat-fused polyimide tape.  | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 650°F (344°C).
      
      Excellent moisture,  chemical resistance, and abrasion resistance
      
      Color coded single conductor & a double wrapped jacket offers easy 
      polarity identification | 
      
      
      Power Plants
      
      Kilns
      
      Petroleum Plants
      
      Aerospace Industry
      
      Cryogenic Applications | 
  
    | KAK | 
    Very tough, 
    durable Kapton* double wrap of heat-fused polyimide tape is applied over 
    each conductor.  Insulated conductors are twisted with a stranded drain wire 
    and the twisted construction is covered with aluminum / Kapton* tape.  The 
    outer jacket consists of a double-wrapped heat-fused polyimide tape. | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 650°F (344°C).
      
      Excellent moisture,  chemical resistance, and abrasion resistance
      
      Color coded single conductor & a double wrapped jacket offers easy 
      polarity identification
      
      Twisted/ Shielded construction 
      minimizes electrical interference | 
      
      
      Power Plants
      
      Kilns
      
      Petroleum Plants
      
      Aerospace Industry
      
      Cryogenic Applications | 
  
    | TFTF | 
    A double wrap 
    of heat-fused TFE tape is spirally applied over each single conductor and as 
    an overall jacket.  Duplex construction. | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 600°F (315°C).
      
      Exhibits all advantages of an extruded product while providing the 
      additional temperature rating.
      
      Excellent moisture,  chemical resistance, and good abrasion 
      resistance |  | 
  
    | TFATF | 
    A double wrap 
    of heat-fused TFE tape is spirally applied over each single conductor.  
    Insulated conductors are twisted with a stranded drain wire and the twisted 
    construction is covered with an aluminum / Kapton tape.  The outer jacket 
    consists of double-wrapped heat-fused TFE tape. | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 600°F (315°C).
      
      Exhibits all advantages of an extruded product while providing the 
      additional temperature rating.
      
      Excellent moisture,  chemical resistance, and good abrasion 
      resistance
      
      Twisted/ Shielded construction 
      minimizes electrical interference |  | 
  
    | PFPF | 
    Color-coded PFA 
    Teflon* is extruded over each single conductor.  A PFA Teflon* jacket is 
    extruded over the insulated parallel singles to form a duplex construction. | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 600°F (315°C).
      
      Excellent moisture,  chemical resistance, and good abrasion 
      resistance
      
      Very smooth on outer jacket facilitates easy pulling of wire through 
      conduits. |  | 
  
    | PFAPF | 
    Color-coded PFA 
    Teflon* is extruded over each single conductor.  Insulated conductors are 
    twisted with a stranded drain wire, and the twisted construction is covered 
    with an aluminum/Mylar tape. A PFA Teflon* jacket is extruded over the 
    shielded pairs or triads. | 
      
      
      Designed for continuous use  to 500°F (260°C);
      
      intermittent use to 600°F (315°C).
      
      Excellent moisture,  chemical resistance, and good abrasion 
      resistance
      
      Very smooth on outer jacket facilitates easy pulling of wire through 
      conduits.
      
      Twisted/ Shielded construction 
      minimizes electrical interference | 
      
      
      Power Generating Plants
      
      Petroleum Plants
      
      Field Heat Treating | 
  
    | TT | 
    Color-coded FEP 
    Teflon* is extruded over each single conductor.  The single insulated 
    conductors are laid parallel and insulated with an extruded jacket of FEP 
    Teflon*. | 
      
      
      Designed for continuous use  to 400°F (205°C);
      
      intermittent use to 500°F (260°C).
      
      Excellent moisture,  chemical resistance, and abrasion resistance
      
      Excellent low-friction jacket facilitates easy pulling of wire through 
      conduits. | 
      
      
      Power Generating Plants
      
      Petroleum Plants
      
      Field Heat Treating | 
  
    | TAT | 
    Color-coded FEP 
    Teflon* is extruded over each single conductor.  Insulated conductors are 
    twisted with a stranded drain wire, and the twisted construction is covered 
    with an aluminum/Mylar tape. A FEP Teflon* jacket is extruded over the 
    shielded pairs or triads. | 
      
      
      Designed for continuous use  to 400°F (205°C);
      
      intermittent use to 500°F (260°C).
      
      Excellent moisture,  chemical resistance, and abrasion resistance
      
      Excellent low-friction jacket facilitates easy pulling of wire through 
      conduits.
      
      Twisted/ Shielded construction 
      minimizes electrical interference | 
      
      
      Power Generating Plants
      
      Petroleum Plants
      
      Field Heat Treating | 
  
    | SFSF | 
    Tough, heavy 
    insulation for use where abrasion resistance on braided insulation is 
    required.  Conductors are insulated  with a braided composite synthetic yarn 
    & impregnated with a color-coded moisture resistant saturant.  The insulated 
    conductors are laid parallel & insulated with a heavy yarn composite 
    synthetic fiber jacket which is then coated with the same saturant.* | 
      
      
      Designed for continuous use  to 550°F (288°C);
      
      intermittent use to 650°F (344°C).
      
      Excellent moisture,  chemical resistance, and abrasion resistance
      
      Excellent low-friction jacket facilitates easy pulling of wire through 
      conduits.   |  | 
  
    | PP | 
    The least 
    expensive extension wire insulation available.  The PVC individual 
    color-coded conductors are insulated with 15 mils (nominal) of PVC, then 
    parallel conductors are given a 20 mil PVC jacket.  The Jacket is easily 
    stripped for separation of insulated conductors for assembly. | 
      
      
      Designed for continuous use  to 220°F (105°C);
      
      Good abrasion & chemical resistance
      
      Excellent moisture,  resistance
      
      Color coded single conductors  &  jacket offers easy polarity 
      identification   | 
      General Plant InstallationPermanent Sensor FabricationTest Facilities | 
  
    | PAP | 
    Single & 
    Multipair cables with an overall shield are constructed by insulating the 
    single conductors with 220°F (105°C) PVC.  One conductor of each pair is 
    numbered and twisted with its counterpart.  The twisted pairs are cabled 
    with an insulated copper communications wire and the entire construction is 
    wrapped with an aluminum/Mylar tape shield.  A copper drain wire is applied 
    under the extruded 195°F (90°C) PVC jacket. | 
      
      
      Designed for continuous use  to 220°F (105°C);
      
      Good abrasion & chemical resistance
      
      Excellent moisture,  resistance
      
      Color coded single conductors  &  jacket offers easy polarity 
      identification
      
      Approved UL Sub 13 PLTC | 
      General Plant InstallationPermanent Sensor FabricationTest Facilities | 
  
    | PAAP | 
    This 
    construction is the same as the above PAP construction, except this 
    construction has an aluminum/Mylar tape and drain wire over each single pair 
    in the construction.  This provides isolation for each separate pair in the 
    construction and eliminates internal and external noise in the circuit. | 
      
      
      Designed for continuous use  to 220°F (105°C);
      
      Good abrasion & chemical resistance
      
      Excellent moisture,  resistance
      
      Color coded single conductors  &  jacket offers easy polarity 
      identification
      
      Twisted/ Shielded construction 
      minimizes electrical interference
      
      Approved UL Sub 13 PLTC | 
      General Plant Applications |